Calculations
Volume of resevoirs: Rippl's method
Default

Input data

Flow table

Inlet flow at each hour
Demanded flow at each hour

Output data

Average flow of the day

Coefficient of the most demanded hour

Minimum recomended volume

Description

Given, for each hour interval or a 24 h day: the inflow and outflow, determines the average outflow, the maximum hour demand coefficient and the minimum revomended volume of the storage tank.

Graphic

References

  • Vianna, Marcos R. Produção, Reservação e Distribuição de Água eBook. Belo Horizonte: Bloom, 2021.