References
- AZEVEDO NETTO, J. M. DE. Manual de hidráulica. 9. Ed. São Paulo, Blucher, 2015.
Given the superficial area of the filter, the washing time, and the desired ascending velocity, the required water washing volume is calculated.
Where:
Filter
| Parameter | Standard units | Description |
|---|---|---|
| Ascending velocity (Ua) | m/min | Desired ascending velocity |
| Superficial area (A) | m² | Superficial area of the filter |
| Washing time (t) | min | Duration of washing |
| Parameter | Standard units | Description |
|---|---|---|
| Washing volume (Vl) | m³ | Total water volume for washing |