Settler: removal efficiency

Input data

Influent flow

Influent suspended solids

Influent volatile suspended solids

Influent BOD5 (total)

Influent BOD5 (soluble)

Suspended solids removal

Surface overflow rate (blank = no area)

Sludge solids content (blank = no sludge flow)

Output data

Effluent suspended solids

Effluent volatile suspended solids

Effluent BOD5 (total)

Settled sludge

Settled volatile solids

Surface area

Sludge flow

Description

Primary or intermediate settling tank described by the fraction η\eta of the suspended solids it removes. The volatile solids and the particulate BOD5 settle in the same proportion as the suspended solids; the dissolved BOD5 passes through:

SSTe=SST(1−η)SSVe=SSV(1−η)SST_e = SST (1 - \eta) \qquad SSV_e = SSV (1 - \eta)

DBOe=DBOs+(DBO−DBOs)(1−η)DBO_e = DBO_s + (DBO - DBO_s)(1 - \eta)

The solids removed leave as sludge:

Plodo=Q SST η1000P_{lodo} = \frac{Q \, SST \, \eta}{1000}

Given a surface overflow rate, the block also returns the surface area A=Q/TASA = Q / TAS; given the solids content of the sludge xsx_s, the sludge flow Qlodo=Plodo/(1000 xs)Q_{lodo} = P_{lodo} / (1000 \, x_s).

Use it after a biofilm reactor or ahead of an activated sludge stage to keep the solids it would otherwise carry out of the mixed liquor. The efficiency is an input, not a result: take it from the settling characteristics of the solids or from the operating data of a comparable unit.

References

METCALF & EDDY. Wastewater Engineering: Treatment and Resource Recovery. 5th ed. McGraw-Hill, 2014.