Moving bed biofilm reactor without aeration, ahead of the aerated stage, fed with the influent and the nitrate recycled from downstream (internal recycle r and, when it returns there, the sludge recycle R). The influent BOD5 is the electron donor. All nitrate returned is assumed removed:
NO3,rem=NO31+R+rR+rNO3,e=1+R+rNO3
The reactor is sized on the volumetric nitrate-N loading, reported as 0.25 to 0.5 kg NO3-N/m³·d for anoxic MBBRs with media of 500 m²/m³ at 50% fill, with a minimum empty bed contact time of 30 min:
V=1000NLTQNO3,remNLT=NL20θ(T−20)A=SSAFV
Carbon used, as bCOD per nitrate-N removed, with the oxygen carried in by the recycle counted as nitrate equivalent:
NC=1−1.42Y2.86DBOdn=DQOb/DBO5C/N(NO3,rem+2.86ODr(R+r))
The BOD5 left for the aerated stage is the influent BOD5 less that used. The reported loadings come mostly from postanoxic reactors with an external carbon source; with the wastewater BOD5 as donor, the lower end of the range is the safer design value.
METCALF & EDDY. Wastewater Engineering: Treatment and Resource Recovery. 5th ed. McGraw-Hill, 2014. Sections 8-7 and 9-7.