MBBR: pre-anoxic (denitrification)

Input data

Average influent flow

Nitrate formed in the aerated stage

Sludge recycle ratio R returned to the reactor

Internal recycle ratio r

Influent BOD5

Dissolved oxygen in the recycle

Liquid temperature

Media specific surface area

Media fill

Nitrate-N volumetric loading at 20 °C

Temperature coefficient of the loading

Anoxic heterotroph yield, g VSS/g bCOD

bCOD/BOD5 ratio

BOD5 per nitrate-N removed (blank = from Y)

Minimum empty bed contact time

Output data

Effluent nitrate

Nitrate removed

Reactor volume

Media volume

Media surface area

Denitrification flux on the media

Detention time on the influent flow

BOD5 per nitrate-N removed

BOD5 used by denitrification

BOD5 to the aerated stage

Oxygen recovered

Alkalinity recovered

Description

Moving bed biofilm reactor without aeration, ahead of the aerated stage, fed with the influent and the nitrate recycled from downstream (internal recycle rr and, when it returns there, the sludge recycle RR). The influent BOD5 is the electron donor. All nitrate returned is assumed removed:

NO3,rem=NO3R+r1+R+rNO3,e=NO31+R+rNO_{3,rem} = NO_3 \frac{R + r}{1 + R + r} \qquad NO_{3,e} = \frac{NO_3}{1 + R + r}

The reactor is sized on the volumetric nitrate-N loading, reported as 0.25 to 0.5 kg NO3-N/m³·d for anoxic MBBRs with media of 500 m²/m³ at 50% fill, with a minimum empty bed contact time of 30 min:

V=Q NO3,rem1000 NLTNLT=NL20θ(T−20)A=SSA F VV = \frac{Q \, NO_{3,rem}}{1000 \, NL_T} \qquad NL_T = NL_{20} \theta^{(T-20)} \qquad A = SSA \, F \, V

Carbon used, as bCOD per nitrate-N removed, with the oxygen carried in by the recycle counted as nitrate equivalent:

CN=2.861−1.42 YDBOdn=C/NDQOb/DBO5(NO3,rem+ODr(R+r)2.86)\frac{C}{N} = \frac{2.86}{1 - 1.42 \, Y} \qquad DBO_{dn} = \frac{C/N}{DQO_b/DBO_5}\left(NO_{3,rem} + \frac{OD_r (R + r)}{2.86}\right)

The BOD5 left for the aerated stage is the influent BOD5 less that used. The reported loadings come mostly from postanoxic reactors with an external carbon source; with the wastewater BOD5 as donor, the lower end of the range is the safer design value.

References

METCALF & EDDY. Wastewater Engineering: Treatment and Resource Recovery. 5th ed. McGraw-Hill, 2014. Sections 8-7 and 9-7.